Lorient LP2004TS (Twin Seal) Fire, Smoke & Acoustic Seal 20 x 4 x 2100mm
Lorient LP2004TS Fire, Smoke and Acoustic (Twin Fin) 20 x 4 x 2100mm Seal
The Lorient TS door seal with double elastomeric fins offers fire, smoke + acoustic protection, with the added benefit of thermal containment.
Available in a choice of sizes to cover 30 and 60 minute applications.
LOCATION – Single + double leaf doors
MIN/MAX GAP SIZE – 3mm/4mm
SEAL MATERIAL – PVC encased sodium silicate + flexible elastomeric fins
TEST EVIDENCE – Acoustic: BS EN ISO 10140-2: 2010. Smoke: BS 476-31.1: 1983. Fire: BS EN 1634-1:2008 & BS 476-22:1987. Durability: 100,00 cycles
PERFORMANCE – Meets smoke requirement: BS 9999: 2017
Carries BBA 92/2841, CERTIFIRE CF330 / CF341 and IFC FRPP454 certification.
Self adhesive backing.
Available in 2.1m lengths in black, brown and white. Other colours / non standard lengths available upon request. Please call 0113 2713 266 or email sales@noberneseals.com for assistance.
Intumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Yes, intumescent strips need to be installed on all fire doors to comply with fire safety standards and building regulations.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
Intumescent strips expand 5-10 times their original thickness, and some can expand up to 20 times their original size to provide passive protection.
Downloads
Unsure about something? Get in touch to ask us a questions
Contact UsIntumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Yes, intumescent strips need to be installed on all fire doors to comply with fire safety standards and building regulations.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.