Pyroplex Fire, Smoke & Acoustic Door Seal, Triple Flipper 15mm x 4mm x 2100mm
This intumescent strip with triple flippers provides fire, smoke and acoustic seals for timber door edges and frames. The flippers are thermally fused to the rigid box section to ensure that they will not delaminate under normal conditions of use. The Integral Flipper range provides added security that will remain uninterrupted when used with ironmongery.
The intumescent strips are supplied in 2.1m lengths as standard, available in 3 colours. They provide a fire, smoke and acoustic seal, & are quick and easy to fit with no special tools required.
Application: Fire resisting timber doorset
Fire Resistance Period: 30 to 60 minutes
Insulation/integrity: Integrity and insulation
Test Standard: BS 476: Part 20:22, BS EN 1634-1 and BS EN ISO 10140-2
Approval Type: Certifire CF822
15 x 4mm available on the website in brown, black and white, other sizes and colours available on request, please email sales@noberneseals.com or call 0113 2713 266.
Intumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Intumescent strips expand 5-10 times their original thickness, and some can expand up to 20 times their original size to provide passive protection.
Yes, intumescent strips need to be installed on all fire doors to comply with fire safety standards and building regulations.
Yes, intumescent strips should be inspected annually for damage or deterioration and gaps.
Downloads
Unsure about something? Get in touch to ask us a questions
Contact UsIntumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Intumescent strips expand 5-10 times their original thickness, and some can expand up to 20 times their original size to provide passive protection.
Yes, intumescent strips need to be installed on all fire doors to comply with fire safety standards and building regulations.
Yes, intumescent strips should be inspected annually for damage or deterioration and gaps.
Unsure about something? Get in touch to ask us a questions
Contact Us