Pyroplex Intumescent Fire & Smoke Door Seal (Brush),10mm x 4mm x 2100mm
Pyroplex Intumescent Fire and Smoke Door Seal, Brush 10mm x 4mm x 2100mm
Pyroplex® Pile range of Rigid Box Seals provide a traditional fire, smoke and acoustic seal for fire rated timber door edges and frames. The range includes a selection of sizes including the wider more traditional solutions. They are suitable for rebates in single and double action, single or double doors. Pyroplex® Rigid Box Seals are ideal for new build applications.
Pyroplex® Pile range of Rigid Box Seals are supplied in 2.1m lengths as standard, and are quick and easy to fit with no special tools required. The Pile range provides fire, smoke and acoustic seals which have been tested to BS 476: Part 22 1987, BS EN 1634-3 and BS EN ISO 10140-2.
CERTIFIRE CertificateNo. CF355.
- 30 and 60 minute systems available.
- Provides fire, smoke and acoustic resistance.
- Supplied with a self-adhesive backer for ease of application.
- Identification on each product ensures full traceability.
- Available in white, brown, black as standard, other colours available on request, please call 0113 271 3266.
Intumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
Yes, intumescent strips should be inspected annually for damage or deterioration and gaps.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Fire and smoke seals prevent the spread of fire and smoke by filling gaps between the fire doors and the door frame. Typically the smoke seals block smoke from spreading before the fire seals activate and provide the full passive protection.
Installation of fire and smoke seals should be fitted around the edges of fire doors and the door frame to provide strong fire resistance and prevention of spreading.
Fire and smoke seals should be inspected every six months and damaged fire and smoke seals should be urgently replaced.
Downloads
Unsure about something? Get in touch to ask us a questions
Contact Us- 30 and 60 minute systems available.
- Provides fire, smoke and acoustic resistance.
- Supplied with a self-adhesive backer for ease of application.
- Identification on each product ensures full traceability.
- Available in white, brown, black as standard, other colours available on request, please call 0113 271 3266.
Intumescent strips are fire resistant passive protection products. When exposed to extreme heat they are activated and expand to control & prevent the spread of fire. Intumescent strips provide passive protection through gaps around doors, fire doors, windows and cable/pipe access.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
Yes, intumescent strips should be inspected annually for damage or deterioration and gaps.
Intumescent strips have a lifespan of 10-15 years when properly maintained and without heavy use of preventing fire from spreading.
When exposed to fire the intumescent material in the strips activate that causes them to expand to 10 times their original thickness. This expansion fills gaps, cracks and prevents flames and hot gases from passing through and spreading.
Fire and smoke seals prevent the spread of fire and smoke by filling gaps between the fire doors and the door frame. Typically the smoke seals block smoke from spreading before the fire seals activate and provide the full passive protection.
Installation of fire and smoke seals should be fitted around the edges of fire doors and the door frame to provide strong fire resistance and prevention of spreading.
Fire and smoke seals should be inspected every six months and damaged fire and smoke seals should be urgently replaced.
Unsure about something? Get in touch to ask us a questions
Contact Us